55 Series 5515 BCR (5515BR)



55 Series 5515 BCR

Application

  • Underwater camera and lights (video system)
  • Diver communications
  • ROV systems
  • Submersibles
  • Towed-array cable systems
  • Current meters
  • Animal migration research


In-house Testing Facility 1: Multimeters

1. Multimeters: It measures a variety of electrical properties. Multimeters are typically used to measure voltage, resistance, and current, in which case they are also known as volt-ohm-milliammeters, as they include wattmeters, ampmeters, and ohmmeters. Some measurement systems include measurements of additional properties, such as temperature and volume. The purpose of this testing method is to ensure DWTEK's subsea connectors are stable and of high quality for multiple applications.


In-house Testing Facility 2: Megger

2. DWTEK’s connectors all have been through the process. This is used to measure the insulation's resistance. This technique uses a comparison principle, where the resistance of the insulation is compared with the known value of resistance. As the insulation resistance rises, the moving coil's pointer goes towards infinity, while as it falls, it indicates zero resistance. 


In-house Testing Facility 3: Pressure Chambers

3. Tested by pressure chambers: stimulate Max. ocean depth of 6,000m and Max. temperature from -20°C to +80°C

55 Series 5515 BCR (5515BR)
Operation and Material Spec.

Operation Specification
Max.voltage 600 V DC
Current rating@contact 4A
Max. current @connector 30A
Insulation resistance >200 Mohm
Contact resistance <0.01 ohm
Depth rating 600 Bar
Temperature rating - 40 to 60˚C

Material Specification
Connector body  Chloroprene rubber
BCR body Brass,Stainless 316,Titanium
Contacts Gold plated brass
FCR leads 8 x 18 AWG PTFE , 60cm
O-rings AS-116

55 Series 5515 BCR (5515BR)
Contact 8

5515_BCR_Male_Contact 8
Order No. Contact
5515BR08M 8

**All product descriptions and specifications are subject to change without notice.